Service manual
C.3c (11xxx) System
Error Description
11020 “Exit Demand Timeout”
When a package in the accumulator does not leave the accumulator
within a given time this error will be displayed.
EVENT: Accum. Package Ready to Exit Demand
EVENT CHECK: ExitDemandTimer
CHECK VALUE: 60 sec.
ADJUST VALUE: Engin. Value 21
ANALYSIS: Time exceeded
11021 "Cover Interlock Open or Emergency Stop Set
EVENT: Interlock OPEN
EVENT CHECK: Interlock
CHECK VALUE: —
ADJUST VALUE: —
ANALYSIS: Interlock OPEN at power ON
11022 "Cover Interlock Open or Emergency Stop Set”
EVENT: Interlock ON
EVENT CHECK: Interlock
CHECK VALUE: —
ADJUST VALUE: —
ANALYSIS: Interlock ON at machine powered
11024 "Exit Sensor Error”
EVENT: Exit Demand
EVENT CHECK: Exit Demand and Exit Sense, Inserter
Station 1 Sense
CHECK VALUE: —
ADJUST VALUE: —
ANALYSIS: Inserter Station 1 Sense covered for 6 demands. Sensor
blocked
11025 "NOT READY"
11028 “Jam Out of Folder”
11029 “Max. No Stop Error Diverts”
C.3d (12xxx) Feeder
Error Description
12001 “No Feed Error”
WHAT HAPPENED
A page was not seen at the Feed Sensor within 500 msec when the
Feeder is processing.
A feed cycle of three trys is taken.
ACTION TO TAKE
Adjust the Feed singulator properly.
Adjust the loading of paper into the Feed singulator properly.
ANY OTHER ADJUSTMENTS
In Test-IO144 look for transitions of the Feeder Sensor Input 0 to 1 as the
lead edge of the paper is manually fed through the Feed Sensor.
PROBLEM ANALYSIS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION C – PAGE 83