Service manual
3 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 7
• Bit 1 = Station 8
• Bit 2 = Station 9
4 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex,
• Package Page Count - 10’s digit
5 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex.
• Package Page Count - 1’s digit
6 ‘0’ —’7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = 0
• Bit 1 = Sequential Stop Clear Accumulator Pack
• Bit 2 = Sequential Stop Stop and Retain Accumulator Pack
7 ‘0’ —’7’ ASCII numbers 0 to 7, 30 hex to 37 hex,
• Bit 0 = Postal Sort Mark, Ink Mark, Kick Mark, Envelope Mark
• Bit 1 = Divert by Read Mark, Divert by Read Errors
• Bit 2 = Pack Valid, Good Pack
8-12 “1 nnnn”ASCII numbers “10000" - ”19999".
• Nnnn is four low digits of group number
13 ‘0’ — ‘9’ ASCII numbers 0 to 9 to 9, 30 hex to 39 hex.
• Internal generated rolling sequence number.
14 CR ASCII Carriage Return, OD hex.
Notes
There is no acknowledge or response from the inserter
General Notes
• There is no acknowledge or response from the Inserter except for 6)
Tampa 1 Protocol,
• Pack Valid or Good Pack.. 11ON: no known errors, 0/OFF; may contain
an error.
• Divert by Read Mark, Divert by Read Errors. 1/ON: divert pack, 0/OFF:
DO NOT divert pack..
• If Divert is ON and Pack Valid is OFF the pack is being diverted
because it may have an error.
• If Divert is ON and Pack Valid is ON the pack is being diverted
because of a read mark..
Read or NO Read(Fixed Pack) Station Selection Operation
• Read
• The machine Inserter Setup Station Selection allows stations to be
selected by read mark or operator set ON, or operator set OFF.
• NO Read
• Normally with Read Off all stations are set ON.
• We will modify the machine to set ON stations which are selected for
read mark or operator set ON. We set OFF only those stations
operator set for OFF,
• Postal Sort Mark/Envelope Mark and Divert by Read will be set
OFF. Pack Valid will be set ON
• Exit Comm Setup Test Button: The package data is set to:
• Number pages = 3
• Pack valid = 1
• Divert = 1
• Ink mark = 1
• Group = 321
• Sequence number = 9
• Station 1 = 1
• Station 2 = 0
INTRODUCTION
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION A – PAGE 71