Service manual
3) Pinnacle 1 Protocol:
Character Data Description
1 ‘0’ -’7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 1
• Bit 1 = Station 2
• Bit 2 = Station 3
2 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 4
• Bit 1 = Station 5
• Bit 2 = Station 6
3 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 7
• Bit 1 = Station 8
• Bit 2 = Station 9
4 ‘0’ -’9’ ASCII numbers 0 to 9, 30 hex to 39 hex.
• Package Page Count - Count 0 to 9 pages.(9, 3A hex, 3B hex etc..)
5 ‘0’ -’7’ ASCII numbers 0 to 7, 30 hex to 37 hex.,
• Bit 0 = 0
• Bit 1 = Sequential Stop Clear Accumulator Pack
• Bit 2 = Sequential Stop Stop and Retain Accumulator Pack
6 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Postal Sort Mark, Ink Mark, Kick Mark, Envelope Mark
• Bit 1 = Divert by Read Mark, Divert by Read Errors
• Bit 2 = Pack Valid, Good Pack
7 CR ASCII Carriage Return, OD hex.
Notes
Characters 1 to 6 are set to ‘9’, 39 hex, if the pack is not valid.
There is no acknowledge or response from the inserter
4) Pinnacle 2 Protocol:
Character Data Description
1 ‘0’ -’7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 1
• Bit 1 = Station 2
• Bit 2 = Station 3
2 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 4
• Bit 1 = Station 5
• Bit 2 = Station 6
3 ‘0’ – ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
• Bit 0 = Station 7
• Bit 1 = Station 8
• Bit 2 = Station 9
4 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex.
• Package Page Count – count 0 to 9 pages.(>9,hex, 3B hex etc.)
5 ‘0’ – ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.
INTRODUCTION
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION A – PAGE 67
071-33370-400