Service manual
• End of Bag. NA.
6 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex. Barcode character 6
• Future NA..
7 CR ASCII Carriage Return, OD hex
Notes
• Characters 1 to 6 are set to ‘9’, 39 hex, if the pack is not valid.
• A 5 msec delay between characters is used. NA
There is no acknowledge or response from the Inserter
2) RR Donnely 2 Protocol:
Character Data Description
1 ‘0’ -’7’ ASCII numbers 0 to 7, 30 hex to 37 hex.. Barcode character 1
• Bit 0 = Station 1
• Bit 1 = Station 2
• Bit 2 = Station 3
2 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex. Barcode character 2
• Bit 0 = Station 4
• Bit 1 = Station 5
• Bit 2 = Station 6
3 ‘0’ – ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex.. Barcode character 3
• Bit 0 = Station 7
• Bit 1 = Station 8
• Bit 2 = Station 9
4 ‘0’ - ‘7’ ASCII numbers 0 to 7, 30 hex to 37 hex. Barcode character 4
• Bit 0 = Station 10
• Bit 1 = Station 11
• Bit 2 = Station 12
5 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex.. Barcode character 5
End of Bag.. NA
6 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex.. Barcode character 6
Future NA.
7 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex. Barcode character 7
—
8 ‘0’ - `9’ ASCII numbers 0 to 9, 30 hex to 39 hex. Barcode character 8
—
9 ‘0’ – ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex.. Barcode character 9
—
10 ‘0’ -’9’ ASCII numbers 0 to 9, 30 hex to 39 hex.. Barcode character 10
11 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex, Barcode character 11
12 ‘0’ - ‘9’ ASCII numbers 0 to 9, 30 hex to 39 hex.. Barcode character 12
13 CR ASCII Carriage Return, OD hex.
Notes
• Characters I to 6 are set to ‘9’, 39 hex, if the pack is not valid.
• A 5 msec delay between characters is used . NA
• There is no acknowledge or response from the Inserter.
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION A – PAGE 66
071-33370-400
INTRODUCTION