Service manual

Line Read Setup 2
(“Setup” > “Line Read” > “Setup 2”)
Lines / Inch:
The code marks can be at 1/6, 1/8, or 1/10 inch spacing. This is 6, 8, or 10
lines per inch. There can be as many as 25 mark locations in a bank.
EXAMPLE
GRV
EOG
GS1
GS2
GS4
GS8
PS1
PS2
PS4
PAR
NOTE: Presence of a bar is binary 1, and the absence of a bar is binary 0.
The GRV mark must be located in the first position. The EOG, PAR, GSn,
and PSn marks may be shifted in the bank of marks. The GS grouping and
the PS grouping must be located as sets, however.
Probes A/B:
Select the reading probe to be used.
Bit Weight:
Page and Group marks can be arranged as Most Significant Bit First (MSB)
or Most Significant Bit Last.
MSB First is the first bit encountered when reading.
MSB Last is the last bit encountered when reading
Example MSB Last Example MSB First
GRV GRV
EOG EOG
GS1 GS8
GS2 GS4
INTRODUCTION
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION A – PAGE 49
071-33370-400