A.6k Inserter Setup 2
Envelope Station Vacuum:
• Normally enabled at “230.” This is the position of the encoder (in
degrees) at which vacuum is applied to the envelope hopper. Station is
normally set at 2.
Envelope Flap Detect:
• Normally set On at: 010, Off at: 350, and Station at 1 (this is the location
of the flap detect).
Ink Mark:
• An optional device that places an ink mark in varying locations to sort zip
codes visually. ON At: (default = 200) Off At (default = 10) is the number
of chain movements AFTER envelope insertion. Ink Marking is normally
located at Station 7.
PM Divert – (Postal Meter Divert):
• (see “Inserter Setup 3” on following page)
• This is normally set On At 10, Off At 10, Station 9, Point 9.
Insert Station Vacuum:
• On is normally enabled at “100.” This is the position of the encoder (in
degrees) at which vacuum is applied to the insert station.
• Logical Shift is normally set to “On At: 90.” This is used to carry the data
with the physical document.
• Bad Pack Stop is normally set to “On At: 80.”
Kicker:
• The Kicker routine is initiated by the extraction of an Ink Mark from read
data.
On Time:
• Period of time in milliseconds that the Kicker will be ON or energized -
Default = 250, “Station” must be set to greater than “0.”
Delay:
• Period of time in milliseconds to delay the Kickers ON time from
occurring. Range (0 ® 990). . Default = 100
Station:
• Location on the deck of the inserter the Kicker will operate from when
selected. Range (0 ® 25). “0” disables the kicker routine. Station is
referenced from the envelope insertion station in “Inserter” and from the
first station in “InserterP” outside of the transfer conveyor.
Shift At:
• Logic shift for data; adjustable to enable data to be shifted relative to
inserter Home position thereby ensuring the “Kick” comes at precisely the
correct moment. Default = 150. Range (0 to 990).
INTRODUCTION
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION A – PAGE 41
071-33370-400