Service manual

GBR Line Code
Bar Code (3 of 9), (2 of 5) (128)
A.4 RUN SCREEN
This screen is displayed continuously for informational purposes until “Test”
or “Setup” is selected.
(See A.7 of this Section for “Setup” Screens)
(See Section C “Problem Analysis” for “Test” screens.)
Run – The current screen.
Test – Press to enter diagnostic screens (for more information, refer
to Section G).
Setup – Press to enter setup screens (for more information, refer to
A.7).
Power On/Off Indicator: Displays status of machine.
Release Brakes – Releases and activates Accumulator and Feed
Brakes to allow jam clearing.
Information Displayed:
Revision (Software) and Build Date – top line
Packages – Total package counter. To reset go to System Setup
Screen. Also resets during bootup.
Sheet – Displays the # of sheets in the accumulator.
Total Sheets – Displays the number of sheets fed from the time the
system was powered up. Resets on machine power down.
Pack Rate – Used to monitor throughput of the 420T. Calculated at
every pack dumped from accumulator (not averaged).
Demand Rate– Displays the package demand rate from the inserter.
Calculated at every demand signal transition (not averaged).
Date and Time – Displayed in the upper right hand corner.
EOG – Displays end of group (ready for dump).
Group – Displays group sequence number after read.
Page – Displays page sequence number after read.
Total Diverts – Displays the number of diverts since the start of the
run.
Batch - displays “Batch Sheet” or “Batch Package” count, resets on
sequential stop
Insert Marks – Displays which insert are selected after each read.
Control Marks – Displays any controls marks, such as IM (Ink Mark)
after read.
Diagnostic – Internal timing
Monitor Events – Displays event history, however, entire list is lost
when power is turned off.
Status – Displays machine status such as “Power Off”.
INTRODUCTION
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION A – PAGE 27