50 0
“ReadLess Read Mode” (Range: 0 > 1, Inc: 1,
Default = 0)
0 = Default. Normal operation.
1 = Special error recovery routine when using Demand
Feed type “Read first” in barcode for FPF-35.
51 1
“First pack Dumped Error Enable” (Range: 0 > 1,
Inc: 1, Default = 1)
1 = Default. Normal operation.
0 = Disables setting bad pack on first pack processed
after startup or purge.
52 1
“Feed & Accum pack Error Enable” (Range: 0 > 1,
Inc:1,Default = 1)
1 = Default. Normal operation.
0 = Disable setting bad pack on Feeder or Accum.
Errors.
53 0
“Inserter Error Pause mode Switch” (Range: 0 > 7,
Inc: 1, Default = 0)
0 = Default. Normal operation
1 = Pulse I/O (1:16) upon a read or processing error.
2 = Pulse I/O (1:16) upon a Demand Feed occurrence
while accumulating a package.
3 = combines functions 1 & 2
4 = Steady state on I/O (1:16) upon a Demand Feed
occurrence while accumulating a package.
5 = combines functions 1 & 4
6 = Illegal combination.
7 = Illegal combination.
54 0
Xfer Cvyr Dat Shift Point (0=Feed, 1=Trk, 2=Fd/180,
3=Trk/180) [note to myself: need something here from
31264008?]
55 0 XferCvyr Error: Set All Stations Not Valid
56 0 XvyrN: Settle At Station Time
57 100 FPH Acc Dump Done Time