Service manual
37 0
“Exit comm. Xmit Retries” (Range: 0 > 2, Inc: 1)
1 + Default. In Tampa 1 only, if no Ack Response is
received defined in EV#36, a retry is initiated and
sends a duplicate serial string. A range of 0->2 retries
can be indicated before the machine stops and
displays the error: “Exit Comm: No Message
Response (E20801)”. (See EV#36 for time setting). If
set to =0, no retries are initiated and if an Ack
Response is not received in the allotted time (EV#36),
an error is generated.
38 2
“Barcode Reader (1=AS 30+, 2=MS911. 3=DL2031)”
(Range: 1 > 3, Inc: 1)
Default = 2. Will select the Start and Stop protocol for
either an Accusort Model 30+ or a microscan MS911.
1 = Accusort Model 30+ Bar Read Start Serial Trigger
= “S” Bar Read End Serial Trigger = “E”
2 = (Default) Microscan MS911 Bar Read Start Serial
Trigger = “” Bar Read End Serial Trigger = “”
3 = DataLogic 2031 Bar Read Start Serial Trigger =
“S” Bar Read End Serial Trigger = “E”
39 0
“Bad pack, Retain Selects? (1=Yes, 0+no)”
(Range: 0 > 1, Inc: 1), Default = 0)
0 = Default. Normal operation. Upon Bad Pack, select
and evelope bits are set to zero.
1 = Upon Bad Pack, select and envelope bits are
retained.
40 1
“Electronics? (1 = New, 0 = Old)” (Range: 0 > 1,
Inc: 1, Default = 1)
1 = Default. Enables I/O configuration for new
modular electronics.
0 = Enables I/O for classic 420 two rack electronics.
41 0
“Sequential Stop Cycles (0=Off)” (Range: 0 > 99,
Inc: 1, Default = 0)
0 = Default. Normal operation.
1 – 99 = Demand cycles after package leaves transfer
conveyor that I/O point 0:16 “Inserter Stop” is
asserted upon the occurrence of a Sequential Stop
command.
42 70
“Max. pages in track 1 – 200” (Range: 1 > 200, Inc:
1, Default = 70)
Used with Flat Feeder configuration. Limits maximum
pages that can be accumulated in a track section.
43 0
“Feed Sensor interrupt (1=ON, 0+OFF)” (Range: 0
> 1, Inc: 1, Default = 0)
0 = Default. Utilizes poling method for input.
1 = Utilizes interrupt method for input.
44 1
“Accum Pack Bad: Set Pack After Bad Also”
(Range:0 > 1, Inc:1, Default = 1)
1 = Default. Upon occurrence of a bad pack, the next
pack processed is tagged as bad also until a good
pack is processed.
0 = Next pack, if no error in normal processing, is not
tagged as a bad pack.
45 1
“Accum Pack has Single: Set Pack Bad” (Range: 0
> 1, Inc:1, Default = 1)
1 = Default. Upon a single cycle accumulation of a
pack in the accumulator, the pack processed is tagged
as bad.
0 = pack is not tagged as a bad pack.
46 1
“Accum Pack Bad: Set Previous Pack Bad Also”
(Range: 0 > 1, Inc: 1, Default = 1)
1 = Default. Upon occurrence of a bad pack, the
previous pack processed is tagged as bad pack also.
(pack in Xfer conveyor).
0 = Previous pack, if no error in normal processing, is
not tagged as a bad pack.
47 0
“Flap Detect IO Inversion (1=Invert, 0+Normal)”
(Range: 0 > 1, Inc:1, Default = 0)
0 = Default. Normal operation.
1 = Logic inversion for the signal. (Incserco
mailcrafter).
48 0
“Intrack Sns Method (0=Normal, 1=Subset-pause)”
(Range: 0 > 1, Inc: 1, Default = 0)
0 = Default. Normal operation.
1 = Support for Subset-Pause operation utilizing both
Transfer Conveyor out Sensor and Intrack/Open Feed
Sensor to track folded subsets in same track.
49 0
“Accum pack Bad: Set Divert By Read Bit”
(Range: 0 > 1, Inc:1, Default = 0)
0 = Default. Normal operation.
1 = Sets Divert by Read bit if the pack is not valid.
MISCELLANEOUS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION F – PAGE 139
071-33370-400