Service manual
19 0
“Test ExitComm Test List Switch” (Range: 0 >
255, Inc: 1)
0 = No extra ExitComm (Comm3) list messages. 1 =
Extra ExitComm list messages, times in msec,
Demand time, receive character (for Sure-Feed). Bit
level assignment: (D7 D6 D5 D4 D3 D2 D1 D0. D7 >
D1 = unassigned D0 = ExitComm messages
20 0
“Exit Demand Switch” (Range: 0 > 1, Inc: 1)
Applies to Hopper Fill and Conveyor. 0 = No Exit
Demand required. 1 = Exit Demand required (for
Conveyor for Sure-Feed).
21 215
“Exit Demand Time Out” (Range: 0 > 999, Inc: 1)
Default 60 = 60 seconds to shut down on no demand.
Range 0 to 999 seconds.
22 3000
“Xcvy Jam At Out Time” (Range: 0 > 9000, Inc: 10)
Default 3000 = 3000 msec to pass pack through exit
sensor. Range 0 to 9000 msec.
23 350
“Xcvy Jam At In Time” (Range: 0 > 9000, Inc: 10)
Default 500 = 500 msec to pass from folder to in
sensor. Range 0 to 9000 msec.
24 250
“Feed to Accum Time” (Range: 0 > 5000, Inc: 10)
Default 170 = 170 msec for the lead edge of paper fed
at the feed sensor to the lead edge entering the
accumulator. Range 0 to 5000 msec.
25 1
“Advance Feed Switch” (Range: 0 > 1, Inc: 1)
1=ON, allows the next pack to be started when the
Accumulator is supposed to dump plus the
Accumulator Dump Time. 0=OFF, starts the next pack
after Accumulator Presence Sensor is cleared plus the
Accumulator Dump Time. When EV #25 is set to “1”,
EV’s #1,2,23,24 should be adjusted as close to
numbers on the right of “?” to obtain optimal
performance. These values may vary depending on
type and weight of paper being processed,
environmental conditions, and system tolerances.
26 1
“Comm Hardware Type” (Range: 0 > 1, Inc: 1)
0 = Ziatech, 1 = WinSystems.
27 4444
“Eng Values Password” (Range: 0 > 9999, Inc: 1)
4444 = Default(9561 is backup).
28 1
“Eng Values Enable Password” (Range: 0 > 1, Inc:
1)
1 = Enable(Default), 0 = Disable. This enables or
disables password to access Engineering Values.
29 3
“Max. Exit Demand power On Cycles” (Range:0 >
99, Inc: 1)
3 = Default. Number of inserter demand cycles before
438 outputs a package.
30 2
“Bar Read Commport” (Cycle Machine Power)
(Range: 1 > 2, Inc: 1)
1 = Commport on CPU-PCB. 2 = (Default) Commport
on Serial Expansion PCB.
31 700
“System ON/OFF Time Cycles”. (Range: 500 > 700,
Inc: 5)
700 = Default. Debounce time in msec to acknowledge
cycling of POWER ON Button Presses from OFF to
ON, ON to OFF.
32 100
“Straight Conveyor Table ON Time” (Range: 5 >
500, Inc: 5)
Default – 100. Time in milliseconds for conveyor table
ON time for each pack out of folder.
33 2
“Number of Double Detect Sample Counts”
(Range: 1 > 4, Inc: 1)
Default = 2. Number of Double Detect Sample Counts
per sheet fed. 20msec sample rate.
34 0
“This EV intentionally left blank” (Range: 0 > 1,
Inc: 1)
(Maximum Sheets Allowed to Accumulate moved to
“Accumulator Setup” in version 26412.051).
35 80
“Feed Control Brake Delay Time” (Range: 0 > 160,
Inc: 10)
Default = 130 msec. Allows the page trail to leave the
singulator before the feed brake is applied. Delay
calculation based on sheet length, speed, and this
constant.
36 100
“Exit Comm Recvd Ack Time” (Range: 0 > 500, Inc:
10)
Default = 100msec. In Tampa 1 only, if no Ack
Response is received the machine errors out and
resets the comm. To try transmit again. (See EV#37
for retries.) If set to =0 there is no Exit Comm Rcvd
Ack Timer check and no machine error
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION F – PAGE 138
071-33370-400
MISCELLANEOUS