Service manual

F.4 Engineering Values
These values are to be used as a starting point. These values may vary,
depending on type and weight of paper being processed, environmental
conditions, and system tolerances, in order to obtain optimal performance.
(Eng. Software Version)
#
Value
Description
01 20
“Acc Feed Settle Time” (Range: 0 > 9995, Inc: 5)
Time(msec) after trail edge of last page passes
Accumulator stack sensor into Accumulator until
Accumulator clutch is fired.
02 40
“Acc Dump Done Time” (Range: 0 > 9995, Inc: 5)
Advance Feed ON: Time(msec) from “Accumulator is
going to dump” until next feed is started. A short value
advance feeds, before the pack moves from the
Accumulator. A longer time allows pack movement
detected at the Accumulator presence sensor to start
the next pack feed. Higher is safer, lower is faster, but
assumes pack leaves Accumulator.
Advance Feed OFF: Time(msec) from pack
movement at the detected at the Accumulator
presence sensor to start the next pack feed.
03 150
“Bar Read Time” (Range: 0 > 9995, Inc: 5)
Time(msec) waiting for reader response.
04 250
“Folder Exit Time” (Straight Conveyor Only)
(Range: 0 > 9995, Inc: 5)
Time(msec) allowed for pack to reach the folder exit
sensor.
05 150
“Line Read Time” (Range: 0 > 9995, Inc: 5)
Time(msec) waiting for reader response.
06 10
“Xcvy Dump To Acc Dump Time” (Range: 0 >
9995, Inc: 5)
Time(msec) from “Xcvy is going to move” until next
Accum dump is started.
07 100
“Xcvy Clutch On Time” (Range: 0 > 9995, Inc: 5)
Time(msec) Xcvy clutch is on adjusted for number of
stations. Adjust up/down to place the last pack at the
Xcvy exit.
08 300
“Xcvy Into Station 1 Time” (Range: 0 > 9995, Inc:
5)
09 50
“Xcvy Outof Station 1 Time” (Range: 0 > 9995, Inc:
5)
10 400
“Folder Start To Conveyor Time” (Range: 0 >
9995, Inc: 5)
Should be greater than Eng Value 04, Folder Exit Time
when Exit Type is Conveyor and not in test.
11 0
Test Console Switch” (Range: 0 > 1, Inc: 1)
0 = turns off diagnostics only used in debug mode.
12 1
“Language Select” (Range: 1 > 2, Inc: 1)
1 = English. 2 = English
13 0
“Xcvy Package InOut Counter” (Range: 0 > 9995,
Inc: 5)
Max Number of packages expected in Xcvy. 0
disables this check.
14 150
“Acc Dump Clutch On Time” (Range: 0 > 9995,
Inc: 5)
Constant value Accumulator clutch is on adjusted for
speed. Adjust up so pack fully exits. Adjust down if
next pack is partially pulled under rollers.
15 5
“TouchScreen X Correction” (Range: -60 > 60, Inc:
1)
Constant value for touch sensing. Adjust up to move
sense right. Adjust down to move sense left.
16 -10
“TouchScreen Y Correction” (Range: -60 > 60, Inc:
1)
Constant value for touch sensing. Adjust down to
move sense up. Adjust up to move sense down
17 20000
“Paper Demand Time” (Range: 0 > 60000, Inc: 500)
Time(msec) waiting for paper stack switch in feeder to
be satisfied by infeed.
18 3
“Max Xcvy Stations” (Range: 2 > 6, Inc: 1)
Max Number of package positions in Xcvy “2-6”.
MISCELLANEOUS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION F – PAGE 137
071-33370-400