Service manual

Demand Feed First Page does not expect a Demand Feed Mark on
pages other than the FIRST page fed.(“UNEXPECTED EOG”).
EOG Mark At defines where the Demand Feed mark is.
Last Only
A Gate and/or Demand Feed Mark only set on the last page fed.
All other pages blank. Ignores blank pages.
The Demand Feed Mark can be the same as the Gate Mark. EOG At
would be set to ‘0’.
EOG Mark At defines where the Demand Feed mark is.
1st Only
Marks only on the first page fed.
All other pages blank. Ignores blank pages.
Uses a total number of pages coded in the marks to count to the last page
fed.
Item Verify Mark Setup defines where the the total number of pages are
Set the Page to the total number of pages
Counts Page down to ‘1’. This is the last page fed and ends the set.
Total Page
Uses a total number of pages coded in the marks to count to the last page
fed.
Verifies a Page Sequence for security.
Requires Page Sequence set to Total Up or Total Down.
Item Verify Mark Setup defines where the the total number of pages are.
For Total Page Up, total number of pages must be on each page.
Page Sequence Mark Setup defines where the page sequence marks
are.
For Total Page Up when the Page Sequence matches the Total Page,
this is the last page fed and ends the set.
For Total Page Down, total number of pages may be on each page.
For Total Page Down when the Page Sequence is ‘1’, this is the last page
fed and ends the set.
For Total Page Down the the total number of pages definition, Item Verify
Mark, may also be the same as the Page Sequence Mark setup defines.
BOG Mark
BOG is Beginning Of Group.
This is a mark only on the first page fed. All other pages no mark.
EOG Mark At defines where the BOG mark is.
Barread Demand Feed:
Total Page
Uses a total number of pages bits coded in the barcode to count to the
last page fed.
Requires Page Sequence set to Total Up or Total Down.
Total Page Code Setup defines where the the total number of pages data
is.
Page Sequence Code defines where the Page Sequence data is.
Total Page Code must define the total page count in the barcode on each
page.
For Total Page Up when the Page Sequence matches the Total Page,
this is the last page fed and ends the set.
For Total Page Down when the Page Sequence is ‘1’, this is the last page
fed and ends the set.
For Total Page Down the Total Page Code definition may also be the
same as the Page Sequence Code.
Read First
Barcode on only the first page. All other pages no barcode.
The Barcode on the first page must have a total page count.
Uses a total number of pages bits coded in the barcode to count to the
last page fed.
Total Page Code Setup defines where the the total number of pages data
is.
Requires Page Sequence set to Total Down or Page Down.
Requires Page Sequence Min set to 1.
Counts Page down to ‘1’. This is the last page fed and ends the set.
BOG Mark
BOG is Beginning Of Group.