• Demand Feed First Page does not expect a Demand Feed Mark on
pages other than the FIRST page fed.(“UNEXPECTED EOG”).
• EOG Mark At defines where the Demand Feed mark is.
Last Only
• A Gate and/or Demand Feed Mark only set on the last page fed.
• All other pages blank. Ignores blank pages.
• The Demand Feed Mark can be the same as the Gate Mark. EOG At
would be set to ‘0’.
• EOG Mark At defines where the Demand Feed mark is.
1st Only
• Marks only on the first page fed.
• All other pages blank. Ignores blank pages.
• Uses a total number of pages coded in the marks to count to the last page
fed.
• Item Verify Mark Setup defines where the the total number of pages are
• Set the Page to the total number of pages
• Counts Page down to ‘1’. This is the last page fed and ends the set.
Total Page
• Uses a total number of pages coded in the marks to count to the last page
fed.
• Verifies a Page Sequence for security.
• Requires Page Sequence set to Total Up or Total Down.
• Item Verify Mark Setup defines where the the total number of pages are.
• For Total Page Up, total number of pages must be on each page.
• Page Sequence Mark Setup defines where the page sequence marks
are.
• For Total Page Up when the Page Sequence matches the Total Page,
this is the last page fed and ends the set.
• For Total Page Down, total number of pages may be on each page.
• For Total Page Down when the Page Sequence is ‘1’, this is the last page
fed and ends the set.
• For Total Page Down the the total number of pages definition, Item Verify
Mark, may also be the same as the Page Sequence Mark setup defines.
BOG Mark
• BOG is Beginning Of Group.
• This is a mark only on the first page fed. All other pages no mark.
EOG Mark At defines where the BOG mark is.
Barread Demand Feed:
Total Page
• Uses a total number of pages bits coded in the barcode to count to the
last page fed.
• Requires Page Sequence set to Total Up or Total Down.
• Total Page Code Setup defines where the the total number of pages data
is.
• Page Sequence Code defines where the Page Sequence data is.
• Total Page Code must define the total page count in the barcode on each
page.
• For Total Page Up when the Page Sequence matches the Total Page,
this is the last page fed and ends the set.
• For Total Page Down when the Page Sequence is ‘1’, this is the last page
fed and ends the set.
• For Total Page Down the Total Page Code definition may also be the
same as the Page Sequence Code.
Read First
• Barcode on only the first page. All other pages no barcode.
• The Barcode on the first page must have a total page count.
• Uses a total number of pages bits coded in the barcode to count to the
last page fed.
• Total Page Code Setup defines where the the total number of pages data
is.
• Requires Page Sequence set to Total Down or Page Down.
• Requires Page Sequence Min set to 1.
• Counts Page down to ‘1’. This is the last page fed and ends the set.
BOG Mark
• BOG is Beginning Of Group.
PROBLEM ANALYSIS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION C – PAGE 123