Service manual
To define the Extraction of Demand Feed:
Char. Position 1 2 3 4 5
always start at 1 and count up from left to right.
1 8 9 0 9 for this example.
Define Demand Feed Start = 1
Define Demand Feed Length = 5
Must use the entire number.
Demand Feed Data Extracted = “18909” “18909” is converted
to a number for the math.
Define Demand Feed Bit Start = 1
Binary weight ‘1’ present? Yes = ON
To define the Extraction of Inkmark: (method 1)
Char. Position 1 2 3 4 5
always start at 1 and count up from left to right.
1 8 9 0 9
for this example.
Define Inkmark Start = 1
Define Inkmark Length = 5
Must use the entire number.
Demand Feed Data Extracted = “18909” “18909” is converted
to a number for the math.
Define Demand Feed Start = 1
Define Demand Feed Length = 5 Must use the entire number.
Demand Feed Data Extracted = “18909” “18909” is converted to a
number for the math.
Define Demand Feed Bit Start = 1
Binary weight ‘1’ present? Yes = ON
To define the Extraction of Inkmark: (method 2)
Char. Position 1 2 3 4 5
always start at 1 and count up from left to right.
1 8 9 0 9
for this example.
Define Inkmark Start = 1
Define Inkmark Length = 5 Must use the entire number.
Demand Feed Data Extracted = “18909” “18909” is converted
to a number for the math.
Define Inkmark Bit Start = 3
Binary weight ‘4’ present? No = OFF
To define the Extraction of Insert Sta. 1 to 6:
Char. Position 1 2 3 4 5
always start at 1 and count up from left to right.
PROBLEM ANALYSIS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION C – PAGE 119