Instruction manual
Clear-Com Communication Systems
ICS 92/52 Intercom Panel Instruction Manual
2-5
Refer to the Eclipse Configuration System Instruction Manual for
instructions on muting the speaker.
PAGE VOLUME LEVEL
When Page Override is assigned to a label, the audio level at the
destination panel(s) is predetermined. This function allows talking to
someone even if his panel’s volume control is off. Two things will
happen when a panel activates such a label:
• If the destination speaker was off, it will turn on.
• The panel(s)’s speaker output will be at the predetermined level
regardless of the “Intercom” volume control setting, unless this
control is set higher than the predetermined level.
The page volume level can be adjusted within a range of 0 to 10,
equivalent to the front-panel control settings of 0 equals off and 10
equals full pot. The page volume level’s default setting is 5.
Refer to the Eclipse Configuration System Instruction Manual for
instructions on using Page Override.
PANEL-TO-MATRIX CARD BAUD RATE
The RS-422 serial data communication between a panel and other
devices can operate at standard (19.2 k baud, the default) and
long-line (9600 baud) baud rates. Use long-line only if encountering
problems with the standard baud rate.
The baud rate is set from the configuration program and the panel
automatically adapts.