Service manual

3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
16.
Lift and remove vent back.
Remove the
seven (7) screws securing
Danger Label panel and right rear
panel to fryer. Save panels and screws
for reuse.
Remove
weight from weight lifter and
save for reuse.
Disconnect the two (2) vent solenoid wires
from harness wires at insulated terminals
(See Figure 23).
Remove
the four (4) screws securing vent
block to vent assembly. Save screws, block
and ball (if applicable) for reuse.
NOTE: Some 4-Head and 6-Head models
utilize a stainless steel vent ball (located
on vent block) with weight to regulate
pressure
Remove vent tube O-ring and save for reuse
(See Figure 29).
Remove the four (4) screws securing vent
assembly to rear of fryer and save for reuse.
Leave vent block nut plate on vent tube for
further use.
Remove
defective vent spring and discard.
Replace vent spring securing weight lifter
to solenoid bracket. Vent spring is mounted
between notch in top of vent solenoid
bracket and hole in weight lifter arm.
Manually depress and release weight lifter
several times to ensure smooth, unrestrict-
ed travel prior to reassembly.
Replace the four (4) screws securing vent
assembly to rear of fryer. NOTE: Vent
tube
must
protrude through vent assembly
at least l/2” (See Figure 30).
Connect the two (2) solenoid wires to
harness wires.
Place O-ring over vent tube and slide
back against vent assembly.
WINSTON
52
LIT.6710/REV.0/9-91
FIG.29
FIG.28
FIG.30