Service manual

WINSTON
16
LIT.6710/REV.0/9-91
TROUBLESHOOTING
FAULTS
REMEDIES
*
*
*
*
*
*
*
*
*
*
*
*
*
*
ADJUST
REPLACE
REPAIR
CLEAN
39. Pin loose in molex connector on computer . . . . . . . . . . . . . .
41. Transformer defective . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38. Excessive moisture in shortening . . . . . . . . . . . . . . . . . . . .
40. Power board plug loose or off . . . . . . . . . . . . . . . . . . . . . . .
37. Cotter pin too long or tight (must rotate freely). . . . . . . . . . .
42. Probe defective. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
45. Vent solenoid cotter pin missing. . . . . . . . . . . . . . . . . . . . . .
47. Vent solenoid dirty. . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . .
48. Collector Out of round - defective. . . . . . . . . . . . . .. . . . . . . .
46. Mercury relay defective. . . . . . . . . . . . . .. . . . . . . . . . . . . .
44. Vent Ball stuck on Vent Block (if applicable). . . . . . . . . . . . .
NOTE 1: This fryer is equiped with an AquaLert software system. Software is designed to
stop the heat-up process prior to boiling point when water is detected in fryer. If
51. Solid shortening being melted in fryer (See Note 2). . . . . . . .
50. Fryer filled with water (See Note 1). . . . . . . . . . . . . .. . . . . . .
49. Probe wire(s) disconnected from plug. . . . . . . . . . . . . . . . . .
fryer is filled with water, empty, clean, dry thoroughly and fill with cooking oil.
NOTE 2: When solid shortening is being heated in fryer, the water detection software system
may respond as though water is being heated due to the slower heat curve experi-
enced. When heating solid shortening, remove any pieces which may be lodged next
to temperature sensing probe.
TM
43. Shortening/crackling build up in vent tube. . . . . . . . . . . . . . .