Programming instructions
Collectramatic
®
Fryers – Very Low Pressure/Temperature – LP46, LP56
6
www.winstonind.com
800-234-5286
INSTALLATION
ELECTRIC
The appliance is shipped from the factory without cord. Refer to wiring circuit
diagram (pages 33-35) for installation assistance. The appliance is shipped wired for
a 3-phase application. The fryers may be changed to single phase operation, as
indicated in the chart below. A licensed electrician may be required. Check local
codes.
Following is a copy of the electrical information on the name plate for various
models of Winston’s Collectramatic
®
fryers.
Model Volts Hertz PH Amps Watts Circuit
Amp
LP46 208/240 60 1 37.9/43.7 7875/10.5kw US 50/US 60
208/240 60 3 21.9/25.2 7875/10.5kw US 50/US 50
400 50 3 N/A 7875/10.5kw N/A
LP56 208/240 60 1 37.9/43.7 7875/10.5kw US 50/US 60
208/240 60 3 21.9/25.2 7875/10.5kw US 50/US 50
400 50 3 N/A 7875/10.5kw N/A