Programming instructions
Collectramatic
®
Fryers – Very Low Pressure/Temperature – LP46, LP56
30
www.winstonind.com
800-234-5286
TROUBLESHOOTING
FAULT CODE (continued) CORRECTION
12. Collector gasket dirty or damaged .................................. Clean or Replace
See pages 25-27
13. Deadweight dirty or missing ............................................ Clean or Replace
See pages 25-27
14. Lid gasket dirty, damaged, or missing ............................ Clean or Replace
See pages 25-27
15. Lid valve O-ring not seating, or missing .................................... Clean, Adjust, or
Replace
See pages 25-27
16. Lid valve retainer loose ................................................... Adjust, see page 27
17. Maximum allowable temperature exceeded ................... See page 7
18. Aqualert sensing is activated .......................................... See page 31
[CS]-Call for Service (see below)
If cabinet is in warranty, call Winston Industries at 1-800-234-5286. Identify the
following:
1. Model ___________________ Serial # ________________________________
(located on name plate)
2. Your name ______________________________________________________
3. Company name __________________________________________________
4. Company address ________________________________________________
_______________________________________________________________
5. Company phone _________________________________________________
6. Type of problem _________________________________________________
_______________________________________________________________
_______________________________________________________________
_______________________________________________________________
If cabinet is out of warranty, call the servicer of your choice, or you can call
Winston Industries for an authorized servicer nearest you.