Programming instructions

Collectramatic
®
Fryers Very Low Pressure/Temperature – LP46, LP56
15
www.winstonind.com
800-234-5286
OPERATING
INSTRUCTIONS
FILLING
The following filling procedure is to be used when cooking oil is changed, or when oil
is added for the first time. CAUTION: Prior to using appliance for the first time, perform
the daily cleaning procedure listed on pages 25 through 27.
1. Turn off Power Switch.
2. Clean Fryer per daily cleaning procedure - see pages 25-27.
3. Check Collector and Drain Valve - Make sure collector with gasket is seated
and drain valve is closed (handle back see Figure 3).
4. Lubricate Lid Gasket and Collector Gasket with cooking oil before placing
on fryer.
5. Add Cooking Oil - Liquid or solid cooking oil may be used. Melt solidified
cooking oils in tender or other means and pump into fryer. Add enough cooking
oil to raise liquid to within one inch of Minimum oil level line (see Figure 5). As oil
heats, it expands. Check level again once oil has heated to verify that level is
between Minimum and Maximum marks. CAUTION: Cooking oil may be hot
enough to burn you. Be careful when moving containers of liquid cooking oil.
DANGER: Fire or heater damage may occur when heaters are turned ON unless
they are fully covered with cooking oil.
Heater Coils
Gasket
Drain Valve
Closed
Lifting Loop
Cone
Collector
FIGURE 3 - Some features have been omitted to show greater detail.
Open