User Manual

JDY-25M Super BLE Bluetooth Module
32
10.6 JDY-25M network remote control node wiring diagram
This node is generally used for panel switch and remote controller. The terminal node is generally
powered on sleep. Press the key to send data, and release the key to continue deep sleep
immediately.
Configure remote control node instruction
1.Configure to MESH mode: AT+ROLE5
2.Configured as a low-power consumption node: AT+MCLSS1
3.Restart to take effect: AT+RESET
10.7 Application wiring diagram of network switch panel
Before the installation of the switch panel, it is necessary to configure the module network, and
open the parameters such as AT+SUBTYPE1 and AT+LEARN1 to factory setting, and learn
during installation. The above circuit diagram is the application circuit diagram of the switch
panel. The above two devices support hundreds or thousands of circuit devices in the practical
application.
Example: We control the level of LED2 and LED5 of B switch panel by SW1 of A switch panel.
At this time, LED2 and LED5 of B switch panel need to learn the key of SW1.
Step 1: Make A switch panel enter the code sender mode, click the PWRC pin on A switch panel,
and the LED light on a switch panel flashes slowly, indicating that the code sender mode has
entered.
Step 2: Make B switch panel enter the learner mode, double-click the PWRC pin of the B switch
panel, the ALED of the B switch panel is off, and the STAT pin flashes slowly, indicating that the
learner mode has been entered. First, learn LED2 (press SW2 of B switch panel), at this time,
LED2 light flashes (once a second), then press SW1 of A switch panel code sender, LED2 of B