Owner's manual

10
Alarms
e cooling unit has both an audible notication and a visual alarm indicator (shown in “red” on the control
panel) that are activated when an alarm is triggered. Please note: the HA and LA alarms are disabled during the
rst 23 hours of operation aer the cooling unit is plugged in and/or turned on.
e control panel also will ash a code for each alarm, as follows:
Alarm Code
P1, P3
HA
HA
2
LA
LA
2
What it Means
Probe Failure
e temperature inside the cab-
inet is too warm (above 70°F for
more than 1 hour)
e condenser temperature is too
high (above 140°F for 2 hours)
e temperature inside the cabi-
net is too cold (below 45°F)
e temperature at the condenser
coils (outside the cabinet) has
dropped below the alarm
temperature setting
What to do
Call WineKeeper at 855.511.5113
Check seals, check if door was le open,
lower the ambient temperature
Check for appropriate installation,
ventilation, ambient conditions, and
cooling capacity
Clean the condenser coils
Check for obstructions to the intake and/or
exhaust vents
Check that the condenser fan is operating
Raise the ambient temperature;
Make sure the cold air discharge has
sucient clearance for the air to circulate
Raise the “Minimum Set Point”
Call WineKeeper at 855.511.5113