Owner's manual
10
Alarms
e cooling unit has both an audible notication and a visual alarm indicator (shown in “red” on the control
panel) that are activated when an alarm is triggered. Please note: the HA and LA alarms are disabled during the
rst 23 hours of operation aer the cooling unit is plugged in and/or turned on.
e control panel also will ash a code for each alarm, as follows:
Alarm Code
P1, P3
HA
HA
2
LA
LA
2
What it Means
Probe Failure
e temperature inside the cab-
inet is too warm (above 70°F for
more than 1 hour)
e condenser temperature is too
high (above 140°F for 2 hours)
e temperature inside the cabi-
net is too cold (below 45°F)
e temperature at the condenser
coils (outside the cabinet) has
dropped below the alarm
temperature setting
What to do
Call WineKeeper at 855.511.5113
Check seals, check if door was le open,
lower the ambient temperature
Check for appropriate installation,
ventilation, ambient conditions, and
cooling capacity
Clean the condenser coils
Check for obstructions to the intake and/or
exhaust vents
Check that the condenser fan is operating
Raise the ambient temperature;
Make sure the cold air discharge has
sucient clearance for the air to circulate
Raise the “Minimum Set Point”
Call WineKeeper at 855.511.5113