Features and Specifications
Wine-Mate rack split cooling systems WM-2500~6500SSRWC are designed
and used to provide a cold temperature between 50~65 °F for a properly
insulated wine cellar.
The wine cellar will maintain humidity range within 50~70% RH.
These temperature and humidity ranges like in natural caves are optimized
for long term storage of wine.
SSRWC units consist of a condensing unit and an evaporator unit; they are
connected by a liquid line and an insulated suction line.
SSRWC condensing units can be located away from the evaporator unit 50 ft
so that noise and compressor vibration are isolated.
SSRWC condensing units are water cooled so that exhaust ventilation is not
needed.
SSRWC evaporator units are designed for installation inside a rack or
between two ceiling joists, making them an ideal choice for small and medium
wine cellars. There are also multiple air inlet and outlet doors for different
installations.
Fig. 1 SSRWC Rack Split Cooling System
NOTE:
Capacity is determined under the cellar, the cellar ambient and the
condenser inlet water temperatures of 55°F, 75°F and 75°F, with R13
interior and R19 exterior insulations. Any higher ambient and water
temperatures, lower insulations will cause reducing capacity and the cellar