Specifications
30
Deg F or Deg C
Setting 1
Press the “Down” arrow to change temperature
from Deg F to Deg C.
Press the “Up” arrow to change temperature
from Deg C to Deg F.
Low temperature
alarm set point
Setting 2
Press “Mode” button to advance to Setting 2.
Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 10 Deg. C.
High temperature
alarm set point
Setting 3
Press “Mode” button to advance to Setting 3.
Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 18 Deg C.
Low humidity
alarm set point
Setting 4
Press “Mode” button to advance to Setting 4.
Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 5%.
High humidity
alarm set point
Setting 5
Press “Mode” button to advance to Setting 5.
Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is 95%.
Add or remove
humidifier
Setting 6
Press “Mode” button to advance to Setting 6.
Press the “Up” or “Down” arrow buttons to
adjust to the desired set point. Factory default
is zero (0).
Zero (0) = No humidifier
One (1) = Stand-alone remote mounted
humidifier
Two (2) = Integral Wine Guardian mounted
humidifier (Not for TTW applications)
Fan AUTO or ON
Setting 7
Press “Mode” button to advance to Setting 7.
Press the “Up” or “Down” arrow buttons to
adjust number to the desired set point. Factory
default is zero (0).
Zero (0) = Auto – fan only turns on when
there is a call for cooling or heating
One (1) = Fan On – fan remains on
continuously