温差调整
Differential
temperature
adjustment
16号设定项
Setting 16
使用模式按钮进入16号设定项。
Press Settings button to advance to Setting 16.
使用向上或向下键进行设定。
Press the Up” or Down” buttons to adjust to
the desired setpoint.
本设备及压缩机将在室温超过预设值时启动。
出厂默认值为17摄氏度。
This setting changes the system/compressor; turn
on temperature above setpoint. Factory default is
set to 1 Deg C.
例如:感应器读数12摄氏度
Example: Sensor reading = 13 Deg C
若将此处值设
-17
摄氏度
Setting 16 Set to -1 Deg C
则系统
/
压缩机将在
14
摄氏度时启
System/compressor turns on at 14 Deg C.
死区设定
Deadband setting
17号设定项
Setting 17
使用模式按钮进入17号设定项。
Press Settings button to advance to Setting 17.
使用向上或向下键进行设定。
Press the Up” or Down” buttons to adjust to
the desired setpoint.
此处值为增温与制冷点之间可容许的最小温
差。最大值为3摄氏度,最小值为1摄氏度。出
厂默认值为2氏度。
This setting is the minimal allowable temperature
difference between heating and cooling setpoints.
Maximum is 3 Deg C, minimum is 1 Deg C.
Factory default is set to 2 Deg C.