User guide

34
3.2 STARTING UP MODEL WINE C18S(R) (WITH HEATER)
3.2.1. CONNECTING THE AIR-CONDITIONER
When you plug it into the electrical socket. The fan in the cellar starts up immediately. The compressor
may not come on until 2 minutes later if the temperature of the cellar is higher than the set temperature. If
the temperature of the cellar is the same as the setting on the thermostat, the compressor will not come
on.
3.2.2 SETTING THE TEMPERATURE
The setting of the targeted temperature of the cellar is made on the thermostat .
Use the following process
:
Press the button one second. Press then the button , the set temperature of the cellar will appear.
Use again the button to increase the temperature or the button to lower the temperature. When the right
temperature is set, press the button to confirm it.
- INDICATOR flickering = cold mode on standby
- INDICATOR lit fixed = engaged cold mode (compressor)
- INDICATOR lit fixed = defrost
- INDICATOR lit fixed = heat (resistance)
- INDICATOR lit fixed = fan
On all the guides except C25.
3.3 AUTOMATIC DEFROST
The program of the thermostat will run an automatic defrost time several times a day.
During this position, the compressor cannot start. Only the fan in the cellar can function.
The condensate water produced during this period will be evacuated through the tube