WALL MOUNT SERIES User’s Manual RA-60TB30SS RA-60TB36SS RA-60TB42SS RA-60TB48SS NOTE: Ductless operation is supported as an additional option. For ductless operation, please refer to the ductless kit. For residential and indoor use only Please read this operation manual thoroughly before using your range hood. Store it in a safe location for when you need to reference it in the future.
TABLE OF CONTENTS 1 Table of Contents Safety Information .............................................................. 2 – 3 Content Checklist ..................................................................... 4 Measurements ........................................................................... 5 Preparation ............................................................................... 6 Installation ...........................................................................
2 SAFETY INFORMATION SAFETY INFORMATION TO REDUCE THE RISK OF A FIRE, ELECTRICAL SHOCK, AND/OR INJURY OBSERVE THE FOLLOWING: Unit is intended for indoor residential use only. If you should have questions, contact the manufacturer at the address or telephone number listed in the warranty. In case the unit should need to be cleaned or repaired, switch power off at either breaker or by disconnecting the power cord from the outlet.
SAFETY INFORMATION 3 TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Regardless of heat level, never leave any surface materials unattended while operating an open flame. Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). Depending on amount of usage, clean ventilating fans and filters frequently. Grease should not be allowed to accumulate on fan or filter. For instructions on the how to clean, see maintenance page.
4 CONTENT CHECKLIST CONTENT CHECKLIST 1. CONTENTS INCLUDED a. (1) RA-60TB series (30”, 36”, 42” or 48”) hood assembly b. (1) Lower duct cover (14-1/4”) c. (1) Upper duct cover (14-1/4”) d. (1) User’s manual e. (1) 6” – 7” transition collar f. (2) Baffle filters (RA-60TB 30” model only) g. (3) Baffle filters (RA-60TB 36” / 42” model only) h. (4) Baffle filters (RA-60TB 48” model only) i. (1) Screw packet 2. CONTENTS NOT INCLUDED a. RA-60TBEXTDC (Extension duct cover) b.
MEASUREMENTS 5
6 PREPARATION PREPARATION 1. BEFORE YOU START **BE SURE YOUR UNIT WILL FIT YOUR CEILING HEIGHT** a. Be sure you have all the content of your purchase and required tools for this installation. b. Installation may take at least 1 to 2 hours from start to finish. c. Plan to use as few elbows or turns as possible for more efficient air flow. d. Collar size may need to be increased if utilizing a long duct run. e. At least 12” of vertical duct is required before any turn. f.
INSTALLATION 7 INSTALLATION 1. WALL MOUNT INSTALLATION a. Make sure all preparation steps are completed. b. Determine your ceiling height to see if you need an extension. i. Hood unit height = 12-1/4” ii. Duct cover minimum height = 19” iii. Duct cover maximum height = 35-1/2” iv. (OPTIONAL) Extension duct cover height = 47” c. Determine the location you want to install the range hood. (Fig. 2a) d. Prepare back wall frame with cross wood support. e.
8 INSTALLATION 3. COLD WEATHER INSTALLATION (OPTIONAL) a. Check with your local building codes to see if a CFM reducer is an acceptable alternative to make-up air. b. Remove the RA-60TBCFMR (CFM reducer) and inspect for any sign of defect or damage. (ie. Cracks, broken flips) c. AFTER COMPLETING Step A – G of Section 1 WALL MOUNT d. Place the CFM reducer onto the outlet of the unit and seal the connection INSTALLATION point with aluminum tape. (Be sure it is secure with no opening or gaps) e.
INSTALLATION DIAGRAM INSTALLATION DIAGRAM 9
10 OPERATION & FEATURES OPERATION & FEATURES 1. EASY ACCESS CONTROL SWITCH (from left to right) a. Button 1 – Power ON / OFF b. Button 2 – Low speed c. Button 3 – Medium speed d. Button 4 – High speed e. Button 5 – Lights ON/OFF a b c d 2. BAFFLE FILTERS a. (2) 14-7/8” x 10-5/8” baffle filters (30” model only) b. (3) 14-7/8” x 10-5/8” baffle filters (36” / 42” model only) c. (4) 14-7/8” x 10-5/8” baffle filters (48” model only) 3. CHARCOAL FILTERS a.
CLEANING & MAINTENANCE 11 CLEANING & MAINTENANCE WARNING!!! To prevent the possibility of a fire and explosion, do not use flammable liquids or solvents to clean the unit or any of its parts. Check to make sure all power sources are disconnected before servicing or taking unit apart for cleaning. 1. RANGE HOOD a. Use household cleaner to remove grease or dirt from the outer shell of the unit. Spray on wiping cloth or sponge and wipe in the direction of the grain to avoid scratching the unit.
12 TROUBLESHOOTING TROUBLESHOOTING WARNING!!! Check to make sure all power sources are disconnected before starting any troubleshooting. Safety gloves and glasses should be worn when working on the unit. Serious injury or death may occur if safety precautions are not followed. RA-60TB Series Light issue (All not turning on) New transformer/ driver replacement is required. LED light issue 1. Check all wiring to and from the unit. 2. LED may require new fixture or transformer.
PART LIST / REPLACEMENT 13 PART LIST / REPLACEMENT # Description # Description 1 Duct cover bracket 8 Control Bracket 2 Duct cover 9 LED transformer 3 Duct cover holder 10 Capacitor 4 Hood bracket 11 Squirrel cage motor 5 Hood body assembly 12 Oil collector 6 LED lights 13 Baffle filters 7 Switch 14 6” – 7” round collar
14 WARRANTY / CONTACT US WARRANTY / CONTACT US LIMITED WARRANTY Windster Hoods Inc. warrants its product against defects in material or workmanship as follows: Labor: For a period of one (1) year from the date of purchase, if the product is determined to be defective, Windster will attempt to repair the product, at its option, at no charge. After the warranty period, customer must pay for all labor charges. During the "labor" warranty period there will be no charge for any work done on the purchased model.
WARRANTY / CONTACT US 15 WHAT IS NOT COVERED BY MANUFACTURE WARRANTY 1. Damages resulting from any of the following: a. Improper installation or maintenance b. Any repair, modification, alteration or adjustment not authorized by the manufacturer or an authorized service dealer c. Misuse and/or accidents d. Incorrect electric current, voltage or power supply e. Improper setting of any control (Pressing multiple selections at the same time) f. 2.