Operating Instructions (ENG) MODELS: RMBS12 BEFORE S/N12236 RMBS16 BEFORE S/N 16905 Read instructions before operating the machine.
MACHINE DATA LOG/OVERVIEW MODEL _______________________________________ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRESENTATIVE # _____________________ DEALER NAME ________________________________ OPERATIONS GUIDE NUMBER ___________________ PUBLISHED __________________________________________ Copyright 2003 Windsor Industries, Printed in USA YOUR DEALER Name: ______________________________________________________________________________________________
TABLE OF CONTENTS Machine Data Log/Overview. ......................2 Table of Contents ........................................3 HOW TO USE THIS MANUAL How to use this Manual...............................1-1 GROUP PARTS LIST Handle Group..............................................5-1 Base - Motor Group. ...................................5-3 Base - Brush Group....................................5-5 Notes...........................................................5-7 Warranty.............................
HOW TO USE THIS MANUAL This manual contains the following sections: - - HOW TO USE THIS MANUAL SAFETY OPERATIONS MAINTENANCE PARTS LIST The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information: - The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. - Parts may be ordered from authorized Windsor dealers.
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. ! WARNING: To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Do not allow machine to be used as a toy.
HAZARD INTENSITY LEVEL The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: ! WARNING WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
GROUNDING INSTRUCTIONS THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
TECHNICAL SPECIFICATIONS ITEM Electrical Nominal Power Rated Amperage Brush Width RMBS12 RMBS16 Brush RPM Wheels Dimensions – Weight RMBS12 RMBS16 Dimensions – Height with handle Dimensions – Depth Power Cord DIMENSION/CAPACITY 115V 550W 7 Amps 12 inches (30 cm) 16 inches (40 cm) 600 RPM 3 inches (7.5 cm) non-marking grey 40 lbs. (18kg) 44 lbs.
HOW THE MACHINE WORKS Congratulations! You are now the proud owner of a Windsor Rombus Carpet Maintainer. The Windsor Rombus Carpet Maintainer is designed to maintain your carpet using the Rombus Quick Clean, Quick Dry Carpet Care System. By using the Rombus Carpet Maintainer in conjunction with Windsor Red Carpet Rombus Carpet Clean (W145-4) chemical solution, you can perform a regular light cleaning and grooming of your carpet very quickly, and have the carpet dry and ready for traffic within 30 minutes.
MACHINE OPERATION PRE-RUN MACHINE INSPECTION Perform a pre-run inspection to find possible problems that could cause poor performance or lost time from breakdown. Check the rating plate to confirm voltage and frequency is the same as the power supply. NOTE: A 10% variation in voltage is acceptable. STARTING MACHINE MACHINE SHUT-DOWN AND STORAGE 1. Depress the foot switch to power off machine. 2. Lock handle in the upright position. NOTE: Perform pre-run machine check before operating machine. 3.
MAINTENANCE BRUSH CLEANING AND MAINTENANCE DAILY MAINTENANCE After each session or carpet cleaning, the brushes and the brush housing should be cleaned. Before cleaning or changing the brushes, always unplug the machine from the power supply. 1. Clean and inspect brushes. 2. Clean and inspect brush housing and machine. 3. Inspect power cord for wear or damage. This cable will lie on wet carpet. To prevent electrical shock replace cords that are frayed or have cracked insulation immediately.
MACHINE TROUBLESHOOTING PROBLEM No power to machine Electrical Shock CAUSE Dead electrical circuit breaker in fuse box Faulty power cord Power switch failure SOLUTION Check building circuit breaker Replace power cord Replace power switch Faulty circuit breaker Replace circuit breaker Internal wiring problem With machine unplugged, check for and correct, any loose wire connections.
THIS PAGE LEFT BLANK INTENTIONALLY ROMBUS 980124 07/02/03 4-3
HANDLE 3 6 4 5 19 25 1 NOTE: The handle view is shown from the Rear. This is to help clarify how the components are attached to the handle asm.
HANDLE REF PART NO.
BASE - MOTOR 1 2A 2B 3 38 32 31 33 34 29 31 26 25 37 4 24 8 36 5 33 32 35 11 26 27 28 30 19 6 28 20 27 21A 21B 12 24 7 23 8 22 9 10 13A 13B 18 17 16 15A 15B 14A 14B ROMBUS 980124 12/18/03 5-3
BASE - MOTOR REF PART NO.
BASE - BRUSH (END HOUSING) 2 1 6A 6B 7A 7B 5 4A 4B 3 13 8A 8B 9A 9B 10A 10B 12 11 ROMBUS 980124 02/19/04 5-5
BASE - BRUSH REF PART NO.
NOTES ROMBUS 980124 07/02/03 5-7