Carpet Maintainer Operating Instructions
OPERATIONS 
 86269870 08/20/08 
3-3 
MACHINE OPERATION 
PRE-RUN INSPECTION 
Perform a pre-run inspection to find possible 
problems that could cause poor performance or 
lost time from breakdown. Check the rating plate 
to confirm voltage and frequency is the same as 
the power supply. NOTE: A 10% variation in 
voltage is acceptable.
STARTING MACHINE 
NOTE: Perform pre-run machine check before 
operating machine. 
FOR SAFETY: Before starting machine, make 
sure that all covers are in place and secured 
properly. 
1.  Connect the machine to a power supply. 
2.  Release the handle lock. 
3.  (a) Press green button to power on the 
 machine,120V only. 
(b) Set black on/off switch to “on” position, 
 230V only. 
4.  Press green button to start brushes. 
After applying a light spray of diluted interim 
carpet cleaner onto the carpet using a pressurized 
tank sprayer, commence cleaning by pushing and 
pulling the machine slowly over the wetted carpet. 
Move the machine in multiple directions and 
overlapping strokes. 
For best results use Windsor iCapsol or Prochem 
ProCaps products. 
STARTING MACHINE – DELUXE 
NOTE: Perform pre-run machine check before 
operating machine. 
FOR SAFETY: Before starting machine, make 
sure that all covers are in place and secured 
properly. 
1.  Connect the machine to a power supply. 
2.  Release the handle lock. 
3.  (a) Press green button to power on machine, 
 120V only. 
 (b) Set black on/off switch to “on” position, 
 230V only. 
4.  Press green button to start brushes. 
5.  Press and hold blue button to spray chemical. 
Once machine is plugged in spray function is 
operational. 
Apply a light spray of diluted interim carpet 
cleaner onto the carpet using the onboard 
spraying system. Spray chemical while pushing 
the machine forward. Brush the chemical into the 
carpet while pulling the machine slowly over the 
wetted carpet. Move the machine in multiple 
directions and overlapping strokes. 
For best results use Windsor iCapsol or Prochem 
ProCaps products. 
Flammable materials can cause an explosion or 
fire. Do not use flammable materials with this 
machine. 
! WARNING