Windsor™ Manual Installation and Operating Instructions Windsor™ Radon Removal System U.S. Patent # 6,372,024, Item No. 86103 Manufactured by: R.E Prescott Co., Inc. 10 Railroad Avenue • Exeter, New Hampshire • 03833 Phone: (603) 772‐4321 • Fax: (603) 772‐1089 REPRESCOTT.
Windsor™ Radon Removal System The Windsor™ unit from R.E. Prescott Co., Inc. is designed to remove radon gas from water. Radon is a radioactive gas which can cause serious health problems. Inside the unit, air is blown into the incoming water and allowed to bubble upward. This bubbling action releases the radon from the water. Air containing the radon is then collected and vented out.
Windsor™ Radon Removal System Inlet Flow and Pressure Specifications 7 gallons per minute and 50 psi required inlet flow and pressure. Outlet Flow and Pressure Specifications 7 GPM Pump Control w/ 1/2” Pex Figure 1 ‐ Windsor Outlet Flow vs. Pressure Controls and Indicators Bypass valve This stainless steel valve can be used to divert the water flow if a problem develops with the Windsor unit. This valve has a black handle, and is located near the back of the unit. See Fig. 4.
Windsor™ Radon Removal System Operating Instructions Once the Windsor has been installed, it should operate with very little attention. Normal Operation ‐ The unit should not need any operator attention. When water is used in the house, the one gallon draw‐down tank delivers water demand. When the pressure drops to the set pressure, the mechanical pump control starts the Windsor pump to deliver water to the home and refill the one gallon draw‐down tank.
Windsor™ Radon Removal System Note: If blower inlet is connected to draw air from an outdoor source, make sure that no moisture can get into the blower motor. If an outdoor source is desired, a dryer vent kit can be modified by removing the flap check and replacing it with screen. Be sure to install the kit as directed and run the hose down to the floor in the area of the Bubble‐Up® Interactive. Figure 2 – Circuit Box Wiring Connections 10. Open the white circuit box on top of the unit. See Fig.
Windsor™ Radon Removal System Bubble‐Up Blower Mechanical Pump Control Mechanical Pump Control Pressure Switch House Pressure Gauge Air Water Coupling Circuit Box Pump Access Seal Main Water Tank Figure 3 ‐ Installation Points Low‐Water Cutout Switch (See Figure 9) Blower Attachment Clamp Blower Attachment Nipple Solenoid Valves Overflow Pipe Vent Outlet Water Inlet and Outlet (attach bypass valve here) 6
Windsor™ Radon Removal System Figure 4 ‐ Installation Points Yellow Float Switch Cord Mechanical Pump Control Cord Figure 5 ‐ Power Cords Start Up Procedure 1. 2. 3. Set the black handle on the bypass valve to the Service position. Before plugging in the Windsor, identify the plug‐in cords. See Fig. 5. Plug in the yellow cord first. The blower should start, and the solenoid valve should open to begin filling the tank.
Windsor™ Radon Removal System Maintenance Every six months: • Check the operation of the float, pump control, solenoid valve, and the blower by turning on a water tap and allowing it to run. At first, the water will be supplied by the 1 gallon drawdown tank, and then the pump should turn on. A few minutes later, you should hear the blower start and the solenoid valve should open. (The unit cannot remove radon unless the blower is working.) • Shut off the water tap.
Windsor™ Radon Removal System 5. 6. 7. 8. Loosen the 4 nuts on the pump access seal. See Fig. 3. Do not remove the top nuts so that the bolts do not fall into the Windsor main water tank. Note that the direction of the float switch cord is towards the air‐water coupling so that it can be re‐installed in the same position. Lift the pump access seal off of the main water tank. This may require prying with a flat screwdriver or two. Lift and pull out float switch and then pump from the main water tank.
Windsor™ Radon Removal System Figure 6 ‐ Replacement Parts Bubble‐Up Mechanical Pump Control ‐ BUB075 PVC Union – BUB024 Well Seal – BUB012 Pump Assembly, Including Motor, Impellor, and Check Valve – BUB005 Float Switch Assembly BUB007 Figure 7 ‐ Pump Assembly with Control Figure 8 ‐ Accessories 10
Windsor™ Radon Removal System House Pressure Gauge Manual Start Lever 1” PVC Union Figure 9 – Bubble‐Up Mechanical Pump Control – BUB075 Parts Listing Item# BUB003B BUB003C BUB007 BUB008 BUB009 BUB010 BUB011 BUB012 BUB012A BUB012B BUB012C BUB013 BUB014 BUB015 BUB016 BUB018 BUB020 BUB022 BUB022B BUB024 BUB025 BUB026 Description 4” X 31” Bubbling Chamber Liner Windsor Tank Float switch assembly Blower PVC Manifold – air‐water coupling Circuit Box 6” supply cord 16/3, yellow Well Seal, size 5” 5” X 1” Gas
Windsor™ Radon Removal System BUB027 BUB028 BUB030 BUB031 BUB032 BUB034 BUB035A BUB035B BUB035C BUB036 BUB037 BUB038 BUB039 BUB040 BUB041 BUB042 BUB043 BUB044 BUB045 BUB046 BUB048 BUB075A BUB054‐08 1.25" X 41.5" PVC SCD 40 Overflow Pipe 2" X 35" Slotted PVC Downcomer 1/2" X Close Nickel Plated Nipple 1/4” SCD 80 Nipple, Yoke Mount #12 X 1.25" Phil Pan Sheet Metal Screw #12 X 3” Phil HD Flat Tapping Screw 3/8” X 2.
Windsor™ Radon Removal System Start‐Up Data For service, call: _________________________________________________ Installer: _________________________________________________ Address: _________________________________________________ _________________________________________________ _________________________________________________ Serial number: _________________________________________________ Start‐Up Notes Fill Rate: _________________________________________________ Radon in: _________________