Specifications

42
3.1 Care of cladding and keyboard foil
Clean the cladding and the keyboard foil with a damp cloth as needed. In the event of heavy soiling, use soapy
water or diluted suds (do not use strong cleaners or sharp cleaning instruments).
3.3 Overview of intervals between maintenance
A clean boiler saves fuel and protects the environment. Fly ash and combustion residues must be cleaned off the
pellet central heating boiler at regular intervals. Therefore always clean your boiler as required!
Annual maintenance is required in addition to cleaning. This is performed
by WINDHAGER Customer Service or
the customer service PARTNERS and is a prerequisite of the guarantee limitations.
The cleaning and ash removal intervals may be reduced or extended depending on the pellets used (e.g. ash
proportion) and the power consumed by the heating system (frequently switching on and off).
The VarioWIN is equipped with a cleaning interval display. The cleaning request for the combustion chamber
and burner pot is displayed on the InfoWIN and must be reset after cleaning is finished – see section 2.10.1.1.
Care, cleaning and maintenance
3.2 Cleaning and operating implements
Install the hanger with the instructions folder, cleaning and operating implements, dowels and bolts on a wall
in the boiler room / installation room – Fig. 122.
1 . . . . .Folder containing instructions
2 . . . . .Key for cladding door and manual
heating surface cleaning with VarioWIN Premium
3 . . . . .Spatula
4 . . . . .Cleaning brush
5 . . . . .Hanger for installation on the wall
6 . . . . .Cleaning tool or removal device for cone
Fig. 122 Instructions folder, cleaning and ope-
rating implements with hanger
1
2
3
4
5
6