Specifications
63
in.xe™
If Circulation pump is not 
working:
• Verify low level program-
ming configuration.
• Start circulation pump by 
setting temperature set point 
2 °F higher than actual water 
temperature.
98
240 VAC at CP connector: 
Pin 2 & Pin 1 
Pin 1
• If you don't get a voltage 
reading, replace the 
accessory fuse.
• If voltage is as it should be,
  replace circulation pump.
• If not, replace Spa Pack.
Accessory fuse
Pin 2
120 VAC at CP connector: 
Pin 2 & Pin 5
Pin 2
Pin 5
 "Circulation pump doesn't work" step-by-step
• Take voltage reading on 
the corresponding in.link™ 
connector:
  240 VAC: Pin 2 & Pin 1
  120 VAC: Pin 2 & Pin 5
  Your reading should be:
  240 VAC for a 240 VAC pump
  120 VAC for a 120 VAC pump
* Only available on IN.XE-5-XX-XXX