Owner`s manual

15
TROUBLE SHOOTING
SYMPTOM: No blue light glowing in chip or lamp cartridge
PROBABLE CAUSE CORRECTIVE ACTION
1. No power to unit 1A. Check power source and cord
2. Broken or defective 2A. Replace chip or lamp cartridge
chip or lamp cartridge
3. Defective power supply 3A. Return to dealer for warranty
cartridge (ZO-300/302) replacement
SYMPTOM: Blue light glowing but no ozone smell on water surface
PROBABLE CAUSE CORRECTIVE ACTION
1. Ozone is present but smell 1A. Do not add any more chemicals for 24
is obscured by other chem- hours, then recheck
icals in the water
2. Open or leaking air control 2A. Remove air control cap and check
valve (venturi installation) condition of “O” ring - if o-ring is
deteriorated, replace and tighten cap
snugly
3. Lack of suction to ozone 3A. See 2A
supply tubing (venturi 3B. Check for dirty filter or incorrectly
injector installation only) operating pump
3C. Check adjustable jets and open
completely
3D. Check for debris in jets
3E. Check ozone supply tubing check valve
3F. Check if blower is connected to the air
venturi line. This situation requires
an injector assembly.
4. Lack of suction to ozone 4A. See 3B-3E
supply tubing (injector 4B. Jets may need to be sized larger
system only)
SYMPTOM: Cloudy water condition even though the unit appears to be
operating properly
PROBABLE CAUSE CORRECTIVE ACTION
1. Unit and pump not operating 1A. Increase operating time (min. 6 hours
long enough is recommended)
2. Total alkalinity not correct 2A. Adjust total alkalinity betw. 80-150 ppm
3. pH not correctly balanced 3A. Check for proper pH betw. 7.2-7.6
4. Not enough suction 4A. Perform DEL Suction Test. Remove air
control cap and check condition of “O”
ring - replace and tighten cap snugly