Figure 9: SpaECLIPSE/CDS-16 Ozone Chip Replacement
REPLACING THE LAMP CARTRIDGE (ZO-300/302)
1. Turn off the electrical power.
2. Remove the ozone generator from the holding clamps.
3. Remove the ozone supply tubing from the generator cartridge.
4. Loosen the bonding plate screw.
5. Remove the lamp cartridge by gently pulling the ozone generator apart to
separate the cartridges. Wiggling the cartridges slightly will help separate
them.
CAUTION: DO NOT TWIST the cartridges while separating. Twisting
will damage the OZONE GENERATOR and may lead to premature
failure.
6. Installation of the new lamp cartridge is accomplished by reversing the
above procedure. Be careful to align the pins properly. Refer to UNIT
ASSEMBLY at the beginning of this manual.
REPLACING THE LAMP CARTRIDGE (ZO-301)
The ZO-301 is a one-piece, disposable ozone generator. Following 9,000
hours of operation, it is should be replaced with a new generator.