The spa’s mechanical system will run exactly as before. Note: If the pump is
above the water level of the spa and there is not a flapper valve in the strainer
basket housing, the pump may lose its prime on an injector installation. Most
pump/filter systems have this valve. If yours does not, add a DEL CHECK
1/3# check valve (DEL part number C0-0101, not included) between the spa
outlet and the strainer basket housing. Continue to follow the instructions for
the pump, filter, heater, etc., that come with your spa.
Once the ozone generator is functioning properly, there is nothing the spa
owner must do to operate it. It should be hooked up so that it operates
automatically with the spa system. If it does not, refer back to the electrical
section.
MAINTENANCE
A blue glow indicates that the SpaECLIPSE/CDS-16 ozone chip or ZO-300/
302/301 UV lamp is working. The ozone chip and lamp cartridge both have a
life expectancy of about 9,000 hours. They will need to be replaced every two
to three years under normal operation. If you suspect a problem, call the DEL
Ozone Hotline at 1-800-676-1335.
REPLACING THE OZONE CHIP (SpaECLIPSE/CDS-16)
1. Turn off the electrical power.
2. Remove the SpaECLIPSE/CDS-16 from its mounting location.
3. Remove the ozone supply tubing from the generator.
4. Remove the three screws from the back of the unit (see Figure 9, page
13).
5. Remove the base from the unit.
6. Tug the wires connected to the ozone chip to remove it from its housing.
7. Disconnect the high voltage connectors and power connector by pulling
them apart - be sure to note how the wires were connected.
NOTE: Only pull on the hard, white plastic wire connectors. Do NOT pull
on the wires.
8. Discard the old ozone chip.
9. Connect the new ozone chip and push it into its housing so that the white
portion shows through the viewing window on the front of the unit.
10. Replace the base of the unit and tighten the three screws.
11. Attach the ozone supply tubing to the ozone outlet.
12. Re-install unit on spa, reconnect the ozone supply tubing and reconnect
the power cord.