Specifications

To run the slip test mode
n
Enable the slip test mode in the configuration menu.
n
Exit the configuration menu.
n
Insert a slip into the slip station.
n
Push the paper feed button. Two code pages will be printed.
n
To repeat this test, preform steps 3 and 4 again.
To exit the slip test mode
n
Enter the configuration menu again. (See “Configuring the printer”)
n
Disable the slip test mode.
n
Exit the configuration menu.
The printer is on-line and can again communicate normally with the host
computer.
En ab le or dis ab le MICR test mode
MICR test mode tests the MICR operation. In this mode the MICR reads the
characters on a check, but instead of transmitting the values to the software
it prints them out.
MICR test is enabled or disabled by selecting the “Diagnostic Modes”
sub-menu of the configuration menu. See “Configuring the printer” for
instructions on how to enter the configuration menu.
To run the MICR test mode
n
Enable the MICR test mode through the configuration menu. Then exit the
configuration menu.
n
Insert a check into the slip station. (See “Verifying and validating checks”)
n
Once a check is detected by the printer, the platen closes and the
characters are read by the MICR check reader. The decoded data is
printed as characters on receipt paper. The platen is then opened, and
the test is re-started.
n
The printed characters should match the characters on the check. If the
MICR check reader misreads a character, a question mark “?” is printed.
If no characters can be read, “NO MICR CHARACTERS” is printed.
To exit the MICR test mode
n
Enter the configuration menu again.
n
Disable the MICR test mode.
n
Exit the configuration menu.
The printer returns to normal mode and can again communicate with the
host computer.
DIAGNOSTIC MODES
32