Specifications

Programmers Guide TH230/TH230+
78
ESC w n b
Function:
Special Wincor barcode parameter
Code ASCII: ESC w n b n d
1
.. d
k
Code HEX: 0x1B 0x77 0x6E 0x62 n
Range:
n = 16, 79
Description:
n specifies the function.
k specifies the count of following bytes
n Bar code
system
Number
of
characters
Characters Function
16,
79
GS1
Databar
Expanded
k = 1
0~9
Specifies the count of Data-
Segments in one Line. Contains
the barcode more Segments,
the barcode will be wrapped.
If the expand code used with
composite code, 4 segments are
the minimum. Less than 4
segments, the barcode will not
printed.
Count of segments has to be
even. Otherwise setting will be
discard.
If barcode with set segments to
wide for print area, barcode will
not print.
Notes:
Wincor Nixdorf specific function. OLD COMMAND. Use GS ( k pL pH cn fn (cn
= 51, fn = 72) instead. COMMAND will not supported in further releases
ESC w n c
Function: Switch the printer into Sleep-Mode.
Code ASCII:
ESC w n c
Code HEX:
0x1B 0x77 0x6E 0x63
Description: This function immediately starts the Sleep-Mode of the printer when the
memory switch 128-3 is enabled.
Notes:
Wincor Nixdorf specific function