Specifications
Programmers Guide TH230/TH230+
284
Mechanical
Requirements (EC
721)
Operating: 3/3
Class 3M2
Non Operating:
3/1 Class 3M2
Transport: 3/2
Class 3M2
Mechanic test conditions:
Environmental classes/conditions : Stationary operation,
weather protected DIN EN 60721-3-3 Class 3M3 printer on,
printing attempts/printouts during test Transport conditions
DIN
EN 60721-3-2,Class 2M2 printer off Remark: The stress
according to environmental class 3M1 (storage) is contained in
environmental class 3M2 (transport).
Test parameters: Sine Vibration 2-9 Hz-amplitude 1.5mm9-200
Hz-acceleration 5m/s²1 Oct./min., duration: 30 min 2-9 Hz-
amplitude 3.5mm9-200 Hz-acceleration 10m/s²1 Oct./min.,
duration: 30 min
Test parameters: Random Vibration Acceleration spectral
density (ASD):10 to 30 Hz: Rise + 6 dB/Oct. 30 to 200 Hz:
Constant PSD 1m²/s²200 to 500 Hz: - 12 dB/Oct. duration: 30
min each axis
Test parameters: Half-sine Shock acceleration: 40 m/s²; type
LShock duration: 22 ms;50 shocks, each axis and orientation
Shock acceleration: 100 m/s²; type IShock duration: 11 ms;100
shocks, each axis and orientation
Conducted /
Radiated Emission
EN 55022 class B
Electrostatic
Discharge
EN61000-4-2 level 4 (current discharge 8kV, air discharge 15 kV)
Radiated
susceptibility
EN 61000-4-3 and EN61000-4-6 with 10V/m
Fast transient
EN 610000-4-4
Approvals UL, cUL, FCC Class A, EN 60950, CE symbol class B