Specifications

Programmers Guide TH230/TH230+
234
86 Control 2 16-Bit Control-Field for special Settings:
Bit Description
All
0 No user defined characters
1 Reserved
2 Reserved
3 Reserved
Subtype = 1 (JIS) Subtype = 0,2,3,4
Subtype excludive
4 JIS-SHIFTJIS-Conversion allowed Reserved
5 Reserved Reserved
6 Reserved Reserved
7 Reserved Reserved
8 Reserved Reserved
9 Reserved Reserved
10 Reserved Reserved
11 Reserved Reserved
12 Reserved Reserved
13 Reserved Reserved
14 Reserved Reserved
15 Reserved Reserved
88 CodeTableArray[20]
FirstCode
LastCode
OffsetFont
20*8
2
2
4
Code table array
2 Bytes for the first character in table
2 Bytes for the last character in table
Offset to Code Table Structure
Code Table Structure
Offset Field Size Description
0 CharacterWidth 1 Width of character in pixels
1 CharacterHeight 1 Height of character in pixels
2 Reserved 2 Reserved
4 Offset 4 Offset to character image