Specifications
TH230/TH230+ Programmers Guide
165
• Excessive use of this function may destroy the non-volatile memory. As a
guideline, do not use any combination of the following commands more
than 10 times per day for writing data to the non-volatile memory: FS q,
GS ( E (part of functions), GS ( L (part of functions), GS g 0, or FS g 1.
• When a counter reaches its maximum value, its value is reset to 0 in the
next updating process (maximum values for maintenance counter see
page 197).The maintenance counter value can be transmitted by GS g 2.
• n
L
+ n
H
x 256 = 59 (Maximum Head Temperature): This resettable counter
isn’t set to 0 but is set to the actual temperature of the thermal print
head.The maintenance counter value can be used for establishing the
time for replacing consumed parts or cleaning.