Specifications

TH230/TH230+ Programmers Guide
135
The maximum print area in the vertical direction is information used
when graphics are printed with the page mode selected (for the starting
point specified with ESC T is “Upper right” or “Lower left”). In this case,
bit images rotated by 90 degrees or 270 degrees are printed.
See Functions 5 and 6 of GS ( E for the paper width and paper (two-color
paper / monochrome paper).
See Functions 3 and 4 of GS ( E for the memory switch.
Vertical Horizontal
Dot
density
Maximum print area (dot)
Dot
density
Maximum print area
(dot)
Paper width
80 mm
Paper width
57.5 mm
203 dpi 576 408 203 dpi 1662
GS ( k p
L
p
H
cn fn [parameters]
Code ASCII:
GS ( k p
L
p
H
cn fn
Code HEX: 0x1D 0x28 0x6B p
L
p
H
cn fn
Range: 2 ≤ (p
L
+ p
H
× 256) ≤ 65530 (0 p
L
≤ 255, 0 ≤ p
H
≤ 255)
cn = 48, 49, 51
fn = 65, 66, 67, 68,69,70, 80, 81, 82
Description:
cn fn Function name
0
0
All: Erase symbol storage area
48
65
PDF417: Set the number of columns in the data region
66 PDF417: Set the number of rows in the data region
67 PDF417: Set the width of the module
68 PDF417: Set the row heigth
76 PDF417: Set ratio of width to heigth
80 PDF417: Store the data into the symbol storage area
81
PDF417: Print the symbol data in the symbol storage area
49 65 QR Code: Select the model
67 QR Code: Set the size of module
69 QR Code: Select the error correction level
80 QR Code: Store the data into the symbol storage area
81 QR Code: Print the symbol data in the symbol storage area
51 72 GS 1 Databar: Set count of modules for GS 1 DataBar Expanded
Notes:
TH230+ only, Firmware 01.07 or newer