Specifications
Programmers Guide TH230/TH230+
106
Sleep-Mode waiting time (a=14)
(n
L
+ n
H
* 256) Waiting time Default
0 Endless TH230 10 sec
TH230+ 1 min
10 … 2550 Time in sec
This value sets the time how long the printer is waiting before Sleep-
Mode starts. The value corresponds to the waiting time in seconds (i.e.
CV14 = 30 -> Sleep-Mode starts after 30 seconds). The range is from 10
to 2550 with step of 10 (10 seconds to 42,5 minutes). The default value
is 10 seconds. When the printer receives a value that is e.g. between 11
and 19 then the stored result is 10 (rounded down). If the Memory
Switch for Sleep-Mode (128-3 / see page 98) is disabled the printer
ignores this time. The power consumption of the Sleep-Mode is lower
than in normal standby. The operator panel LED’s are switched off but
the power LED is flashing with short on-time and long off-time. The
power pin of the customer display connector is also switched to off. The
Power consumption of a RS232-Interface is a little bit higher compared
to an USB-Interface. The printer leaves the Sleep-Mode by every
transmitted data on the host interface, by pressing the feed button or
power button or when the cover sensor is changed.
NOTE:
• If both Receipt shooting and Sleep-Mode are enabled and the
Sleep-Mode time is equal or smaller than the shooting time the
buffered receipt is not printed out in Sleep-Mode.
• If a macro running, Sleep mode is inactive
• If an error occurred, Sleep mode is inactive
• If no paper inserted, Sleep mode is inactive
Power on (Sleep mode) to Cash drawer opening delay (a=15)
(n
L
+ n
H
* 256) Delay time Default
0 … 5000 Time in msec 1700 msec
This value sets the time how long the printer is waiting after Sleep-Mode
ends before Cash Drawer can be opened. The value corresponds to the
delay time in msec (i.e. CV15 = 1700 -> Cash Drawer opening after 1,7
seconds). The range is from 0 to 5000 with step of 100 (0 seconds to 5
seconds). The default value is 1,7 seconds. When the printer receives a
value that is e.g. between 1 and 99 then the stored result is 0 (rounded
down). If the Memory Switch for Sleep-Mode (128-3 / see page 98) is
disabled the printer ignores this time.