Specifications
Programmers Guide TH230/TH230+
100
• The printer transmits the power-on notification for the following
processes:
− Initializing by turning on the power by switch (except with Ethernet
interface)
− Initializing by hardware reset (except with Ethernet interface)
− Initializing by software reset, such as by transmitting Function 2
(except with Ethernet interface and Ethernet parameter changed)
− Initializing after the service menu functions2 (except with Ethernet
interface and Ethernet parameter changed)
• With a serial interface, the printer transmits a 3-byte notification
without confirming that the host can receive data.
• With Ethernet interface the power-on notification will be not
transmitted after power-on or the command GS 0xFF.
• When communication with the printer uses XON/XOFF control, the
XON/XOFF code may interrupt the “Header to NUL” data string.
• When using the power-on notification together with other status
messages, the status transmitted must be differentiated according to
table Transmit Status Identification (see page 196).
•
The printer must be switched off and on to take effect of changed setting
for “Legacy printer support” memory switch (Msw 128-4)!
• The value for receipt shooting flush time will be set in the customer
value CV 13 (see page 105)
• The disable of power button is only related to the switch off function.
• Memory switch “Original Controller” (Memory switch 128-8) is used to
differentiate between original controller and repaired controller. If the
printer is equipped with its first controller (original controller) this
Memory switch is 0. After a controller change this Memory switch is set
to 1.
• Memory switch “Power Button Delay” (Memory switch 2-7): The delay
time is effective when switching off the device. When switching on the
power button reacts always with no delay.
• Memory switches 1-2: Small receive buffer is not recommended for
normal printer operations! It is not allowed when using a TH230+ fiscal
controller interface.