Specifications
7-22
MiniScan MS-320X Integration Guide
Timeout Between Decodes
Timeout Between Decodes, Same Symbol
Parameter # 89h
When in Continuous triggering mode, this parameter sets the minimum duration of not
decoding data before the scanner decodes a second bar code identical to one just
decoded. This reduces the risk of accidentally scanning the same symbol twice. It is
programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended
interval is 0.6 seconds
Timeout Between Decodes, Different Symbol
Parameter # 90h
This option sets the minimum duration of not decoding data before the scanner decodes a
second (different) bar code. This option is used in Continuous mode to prevent the beeper
from beeping when a different symbol appears in the scanner's field of view before the
timeout period between decodes expires. This is programmable in 0.1 second increments
from 0.0 to 9.9 seconds. The recommended value is 0.0 seconds.
Select the timeout between decodes for the same or different symbols.
1. Scan the option bar code you wish to set.
2. Scan two numeric bar codes beginning on page 7-143 which correspond to the
desired interval, in 0.1 second increments.
To change the selection or to cancel an incorrect entry, scan Cancel on page 7-145.
Timeout Between Decodes -
The Same Symbol
Timeout Between Decodes -
Different Symbols