User`s guide
Power cord selection
6 P4-EPC /B-E1, B-E2 – Operating Manual 1750100230 C
For units set at 230 V (outside of the United States and Canada):
Use a cord set consisting of a minimum AWG according to Table A and a
grounding type attachment plug rated 15 A, 250 V. The cord set should have
the appropriate safety approvals for the country in which the equipment will be
installed and should be marked HAR.
For the United Kingdom
Should the plug on the flexible cord not be of the type for your socket outlets,
do not use an adapter but remove the plug from the cord and discard.
Carefully prepare the end of the supply cord and fit a suitable plug.
WARNING:
THIS APPLIANCE MUST BE EARTHED.
IMPORTANT:
The wires in this main lead are colored in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
As the colors of the wires in the mains lead of this appliance may not
correspond with the colored markings identifying the terminals in your plug,
proceed as follows:
The wire which is colored Green and Yellow must be connected to the
terminal in the plug which is marked with the letter E or by the earth
symbol or colored Green or Green and Yellow.
The wire which is colored Blue must be connected to the terminal which is
marked with the letter N or colored Black.
The wire which is colored Brown must be connected to the terminal which
is marked with the letter L or colored Red.