User guide
Bank 2
DIP Function ON OFF Default
1 Auto line Always Always
feed enabled disabled OFF
2 Reserve OFF
3 Font selection 9 x 9 7 x 9 OFF
4 Carriage speed LOW HIGH OFF
5 Busy condition Receive buffer Off-line or
full receive buffer full OFF
6 Document eject and not eject and
Ejection retain retain OFF
7 I/F Pin6 Reset-
Signal Enabled Disabled OFF
8 I/F Pin25 Reset-
Signal Enabled Disabled OFF
9 Document
inverse printing Enabled Disabled OFF
10 Roll width 57,5 * 69,5 OFF
When pin 6 of the interface connector is used for the reset signal, the prin-
ter is reset at MARK (signal level -5 to -15 V, logic “1") on the RS-232C
level.
When pin 25 of the interface connector is used for the reset signal, the
printer is reset at SPACE (signal level +5 to +15 V, logic ”0") on the RS-
232C level or at HIGH on the TTL level.
If DIP switch 7 or 8 of the bank 2 is ON while the printer is turned on, the
printer may be reset, depending on the signal state.
* If you have mounted a spacer in order to use paper rolls with smaller roll
width (see appendix) please set the DIP switch 10 at bank 2 to ON.
DIP switches must not be operated while the printer power is turned on.
Operation of the ND77 DIP Switches
GB - 31