User guide
The DIP switches are allocated as follows:
OFF
ON
Bank 1 Bank 2
Each switch functions as follows:
Bank 1
DIP Function ON OFF Default
1 Cutter Deactivated Activated OFF
2 Parity Enabled Disabled OFF
3 Parity selection Even Odd OFF
4 Transmission speed (see the table below) OFF
5 Transmission speed (see the table below) OFF
6 Connection of
display module* Connected Not connected OFF
7 Data receive
error Ignored Prints ? OFF
8 Handshaking XON/XOFF DTR/DSR OFF
* Effective when a direct connection display module is connected to the
printer`s display module connector.
Transmission speed (BPS) DIP4 DIP5
9600 OFF OFF
2400 OFF ON
4800 ON OFF
19200 ON ON
1
1
2
2
3
3
4
4
5
5
6
6
7
7
9
8
8
10
DSW 1
DSW 2
DIP Switches Operation of the ND77
GB - 30