User manual
To tal Cur rent Con sump ti on Of In ter fa ces
The total current consumption at 5V interfaces must not exceed 5A.
each COM* = 300mA, in total 1000mA
each USB = 500mA, in total 2A
each USB (Hub) = 500mA, in total 2A
TFT/LCD-Display
Max. 5A @ 5V
The total current consumption at 12V interfaces must not exceed 5A.
each COM*(2/3/4) = 600mA, in total 900mA
each COM*(5/6) = 600mA, in total 900mA
each PUSB 12V (*) = 3A
each PUSB 12V = 1.5A
TFT/LCD-Display
Max. 5A @ 12V
The total current consumption at 24V interfaces must not exceed 3A.
each PUSB 24V = 3,0A
24VDC power supply
Max. 3A @ 24V
Power loss of additionally implemented PCI- and PCIe- Controllers is - for
thermic reasons - limited to 10W for each slot and to 20W in total.
BEETLE /S-II plus 41