User guide
To tal Cur rent Con sump ti on Of In ter fa ces
The total current consumption at 5V interfaces must not exceed 5A.
each COM* = 300mA, in total 500mA
each USB = 500mA, in total 2A
each USB (HUB) = 500mA, in total 2A
TFT/LCD-Display
Max. 5A @ 5V
The total current consumption at 12V interfaces must not exceed 5A.
each COM* = 600mA, in total 900mA
each USB = 1,5A, in total 2A
each USB (HUB) = 1,5A, in total 2A
TFT/LCD-Display
Max. 5A @ 12V
The total current consumption at 24V interfaces must not exceed 3A.
each USB (HUB) = 3,0A, in total 3,0A
24VDC power supply
Max. 3A @ 24V
Power loss of additionally implemented PCI- and PCIe- Controllers is - for
thermic reasons - limited to 10W for each slot and all together to 20W.
TO TAL CUR RENT CON SUMP TI ON OF IN TER FA CES
44