User guide

Vertical Installation
Vertical installation
The BEETLE/ M is specified for a horizontal mounting. Observe the
following if the system still is to be mounted vertically:
You will find a drill at the bottom side, so that you can
suspend the BEETLE /M with a screw. To do so, mount two
additional angles at the requested wall so that the BEETLE
can rest upon evenly.
A closed area made of non flammable material (e.g.
concrete or metal) must be located under the vertically
mounted BEETLE /M.
Mount the device in such a way that the ventilator faces
upwards. That is the side with the lesser number of
ventilation slots.
Make sure that the angles do not cover the ventilation slots.
The following minimum clearances must also in horizontal
mounting be provided in free convection to ensure sufficient
ventilation:
horizontal placement: left side: 60 mm, right side: 100 mm
vertical placement: upwards: 100 mm, downwards: 60 mm
hole
Vertical installation
GB - 13