BEETLE /M-II plus (BOS) User Manual 43
Total Current Consumption Of Interfaces
The total current consumption at 5V interfaces must not exceed 5A.
Each COM* = 300mA, in total 500mA
Each USB = 500mA, in total 2A
Each USB (HUB) = 500mA, in total 2A
TFT/LCD-Display
Max. 5A @ 5V
The total current consumption at 12V interfaces must not exceed 5A.
Each COM* = 600 mA, in total 900mA
Each USB = 1.5A, in total 2A
Each USB (HUB) = 1.5A, in total 2A
TFT/LCD-Display
Max. 5A @ 12V
The total current consumption at 24V interfaces must not exceed 3A.
Each USB (HUB) = 3.0A, in total 3.0A
24VPC power supply
Max. 3A @ 24V
Power loss of additionally implemented PCI- and PCIe- Controllers is for
thermic reasons - limited to 10W for each slot and all together to 20W.